To finish the installation

1.
Carefully install the protection cover.
2.
Close and lock the technical box with the key.
3.
Put the cover on the key lock.
4.
Turn on the power from the distribution panel.
NOTE: It may take one to two minutes for the charger
to start.
8
5.
Make sure that the green connector symbol on the front panel activates.

To change the configuration settings

NOTE: For most installations no change of the configuration is needed.
NOTE: CTEK recommend that the installation technician documents the result of
the configuration tests in the dedicated protocol.
1.
If the computer runs on Microsoft Windows, Download the CCU Drivers
from the webbsite. Follow the instructions given on the website.
NOTE: For Linux and Mac OSX, the USB driver is part of the operating system.
2.
Connect the USB cable between the computer and the mini USB port on
the controller board.
User & installation instructions
3.
Open the web browser and log in to the local web interface at
http://192.168.7.2
The user name and password are both "ccu".
NOTE: CTEK recommend web browser Google Chrome for this action.
To configure the network interface (Ethernet)
2
1
5
1.
Navigate to Configuration>Interface>General and select WAN = Wire.
Navigate to Configuration>Interface.
2.
3.
Select Wire.
4.
Select DHCP or Static. If Static is selected, also enter IP address, netmask
and gateway.
5.
Press Save at the bottom of the page.
To configure WWAN (4G)
2
1
5
3
4
3
4