USER MANUAL
CHARGESTORM® CONNECTED 2
MULTILINGUAL
MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for CTEK CHARGESTORM CONNECTED 2

  • Page 1 USER MANUAL CHARGESTORM® CONNECTED 2 MULTILINGUAL MANUAL...
  • Page 2: Table Of Contents

    The charging station is intended for both restricted and non-restricted locations. Part specific data ......10 Product description ...... 2 In the box CTEK E-Mobility warranty statement Intended use ........2 Limited warranty ......11 In the box ..........2 Circumstances that will void the limited warranty Overview ..........
  • Page 3: Status Symbols

    Waiting for cable connection or green authentication. Solid Blue RFID/ Vehicle connected but not charging (for Open example, the vehicle is fully charged or the charging session is paused). Flashing RFID/ Charging in progress. Blue Open CTEK E-Mobility AB User & installation instructions...
  • Page 4: To Charge The Vehicle

    NOTE: There are many different RFID formats. Contact CTEK E-Mobility if your RFID tags are not original CTEK E-Mobility RFID tags to make sure that your RFID tags are compatible with the charging station.
  • Page 5: Installation

    > 2000 mm Mini-USB Remove the protection cover. CTEK E-Mobility AB User & installation instructions...
  • Page 6: To Install The Charging Station On A Pole

    NOTE: For regional differences of the grounding against water. system, such as IT-Nett, refer to the supply input To install the power cable schematic on page 13. Pull the power cable through the cable gland. User & installation instructions CTEK E-Mobility AB...
  • Page 7: To Install The Network Cable And The 3G-Modem (Optional)

    Open ftp to allow remote firmware upgrades. Put the cover on the key lock. Turn on the power from the distribution panel. NOTE: It may take one to two minutes for the charger to start. CTEK E-Mobility AB User & installation instructions...
  • Page 8: To Change The Configuration Settings

    Navigate to Configuration>Interface>WWAN and enter APN applicable for The user name and password are both “ccu”. the selected 3G operator. Leave remaining fields empty. NOTE: CTEK E-Mobility recommends web browser Chrome for this action. Press Save at the bottom of the page. User & installation instructions...
  • Page 9: To Do A Installation Tests

    • If the installation is a Nanogrid Home setup, check the Communication information should be provided by the portal operator. If CTEK E-Mobility's between the external EM and the Charger portal “Charge Portal” is used, the URL to the portal has the format that •...
  • Page 10: Technical Data

    Pollution degree Dimension 449 x 282 x 160 mm Intended for use in EMC H x W x D Environment Material Front and back cover in ABS plastic. Colored zinc oxide metal box for electronics. User & installation instructions CTEK E-Mobility AB...
  • Page 11: Ctek E-Mobility Warranty Statement

    CTEK makes no other warranty than as set out contained in this manual were in effect at printing. herein and CTEK shall in no event be liable for any To make sure that the maintenance instructions are indirect or consequential damages. The faulty...
  • Page 12 W32 BK 6 ¤ Curve C 32A J302 Distr. Rail Energy Meter connect connect Choose one of two options, connect Energy Meter: X16, EM2 & W15, W27-W29 or CAB14 Transformer: CAB14 &W30-W32. OCL Right User & installation instructions CTEK E-Mobility AB...
  • Page 13 Contactor page GY=grey L3_IN HIGH J1001 OG=orange L2_IN PK=pink L1_IN Ferrule RD=red NEUTRAL TEST TEST SNUBBER TQ=turquoise RELAY_OUT 6 FUSE_FB VT=violet W21 BU 1.5 WH=white YE=yellow W34 BK 1.5 YEGN=yellow-green DF11 OCL Right CTEK E-Mobility AB User & installation instructions...
  • Page 14 CAB12 J304 J304 CAB11* EM Left (Always) CAB5 EM Right (dual models) ADDR ADDR OCL Right (dual models) OCL Left (always) * For external MBUS connection CAB11 is replaced by the external cable. User & installation instructions CTEK E-Mobility AB...
  • Page 15 RADIO CT6+ MODEM +12V MOSI PULSE1 MISO +12V PULSE2 Z_RESET M1+LOCK M1+UNLOCK U.FL. USB HOST M2+LOCK M2+UNLOCK +12V Modem CONS1 USB DEVICE +12V CONS2 GND10R +12V GND10R LOCKFB2 +12V 1v98 & higher LOCKFB1 CTEK E-Mobility AB User & installation instructions...
  • Page 16 J503 Cable YEGN 6 YEGN 6 Outlet Outlet CAB15 SOL LOW SOL LOW SOL LOW SOL SENS SOL SENS SOL SENS CAB8 Lock Solenoid CAB8 Lock Solenoid OCL Left OCL Left OCL Left User & installation instructions CTEK E-Mobility AB...
  • Page 17 J503 Cable YEGN 6 YEGN 6 Outlet CAB15 Outlet SOL LOW SOL LOW SOL LOW SOL SENS SOL SENS SOL SENS Lock Solenoid Lock Solenoid CAB9 CAB9 OCL Right OCL Left OCL Right CTEK E-Mobility AB User & installation instructions...
  • Page 18 1PH CABLE RIGHT OUT2 OUT2 U3/U4 J304 Address Termination J503 J503 L3_IN L2_IN L1_IN Cable Cable NEUTRAL RELAY_OUT CAB16 CAB16 SOL LOW SOL LOW FUSE_FB SOL SENS SOL SENS OCL Right OCL Right User & installation instructions CTEK E-Mobility AB...
  • Page 19 WWW.CTEKEMOBILITY.COM 50022553...