Download Print this page

Installation Of Unit - CTEK 250TS Manual

Advertisement

INSTALLATION OF UNIT

1. Attach the temperature sensor holder on a flat surface on one Starter battery. Position it as close
as possible to a positive post.
2. Use the included drill template. Wiring is simplified if the units are installed according to the drill
template, but other setups are possible.
3. Install the unit(s) on a flat surface where it can be properly fixed and where the unit is not
exposed to fuels, oils or splashes of dirt.
4. Mount the unit with screws intended for the surface and attach it with one screw in each of the
four holes in the corners of the unit. See picture 1. Mount the unit with M4 or ST4.2 screws. The
required torque depends on the surface for mounting.
Figure 1
Service ground
Service Battery
24 V+
Starter Battery
2Nm
24 V+
4 • EN
20015884C D250TS, Manual, Print file 002.indd 4
Service Battery Midpoint
Status signal wire
Temp sensor
DRILL TEMPLATE
2011-12-20 13:27:13