Caution – Before you install the system into the cabinet, make sure that the cabinet
is stabilized so that it cannot move or tip forward. See the cabinet documentation for
information about stabilizing the cabinet.
Note – Make sure that each slide assembly is fully retracted into the rack and check
that the ball-bearing runner on each slide assembly is all the way forward.
What to Do
1. With one person on each side of the server, lift the server and approach the
cabinet with the back of the server facing the front of the cabinet.
Note – Do not use the vent holes in the server doors as "handles" to lift the server.
2. Align the rounded ends of the inner glides on the system with the slide
assemblies in the cabinet.
Note – Make sure that the inner glides attached to the system are inserted within
the ball-bearing runners.
40
Sun Fire V440 Server Parts Installation and Removal Guide • July 2003