3. Connect the AC power cords.
As soon as the AC power cords are connected to the system, the ALOM boots and
displays its power-on self-test (POST) messages. Though the system power is still
off, the ALOM is up and running, and monitoring the system. Regardless of system
power state, as long as the power cords are connected and providing standby power,
the ALOM is on and monitoring the system.
4. Open the right-side system door.
Insert the system key into the lock and rotate the key counterclockwise.
5. Insert the system key into the system control keyswitch and turn it to the Normal
or Diagnostics position.
See "System Control Keyswitch" on page 7 for information about each system
control keyswitch setting.
20
Sun Fire V440 Server Parts Installation and Removal Guide • July 2003
System security lock
Right-side system door