Reference for Environmental
Specifications
The operating and non-operating environmental specifications for the system are
as follows.
Parameter
Operating
Temperature
Humidity
Altitude
Vibration (random)
Shock
Non-Operating
Temperature
Humidity
Altitude
Vibration
Shock
Handling Drops
Threshold Impact
Value
5˚C to 40˚C (41˚F to 104˚F) noncondensing—IEC 60068-2-1&2
20% to 80% RH noncondensing; 27˚C max wet bulb—IEC 60068-2-
3&56
0 to 3000 meters (0 to 10,000 feet)—IEC 60068-2-13
2
0.0001 g
/Hz, 5 to 150 Hz, -12db/octave slope 150 to 500 Hz
3.0 g peak, 11 milliseconds half-sine pulse—IEC 60068-2-27
-40˚C to 60˚C (-40˚F to 140˚F) noncondensing—IEC 60068-2-1&2
93% RH noncondensing; 38˚C max wet bulb—IEC 60068-2-3&56
0 to 12,000 meters (0 to 40,000 feet)—IEC 60068-2-13
2
0.001 g
/Hz, 5 to 150 Hz, -12db/octave slope 150 to 500 Hz
15.0 g peak, 11 milliseconds half-sine pulse; 1.0 inch roll-off front
to back, 0.5 inch roll-off side to side—IEC 60068-2-27
60 mm, 1 drop per corner, 4 corners—IEC 60068-2-31
0.85m/s, 3 impacts per caster, all 4 casters, 25 mm step-up—ETE
1010-01