Additional Diagnostic Tests For Specific Devices; Using The Probe-Scsi Command To Confirm That Hard Disk Drives Are Active; Figure 10-2 Probe-Scsi Output Message; Figure 10-3 Probe-Scsi-All Output Message - Sun Microsystems Netra 120 User Manual

Sun microsystems server user's guide
Table of Contents

Advertisement

10.2
Additional Diagnostic Tests for Specific
Devices
10.2.1
Using the probe-scsi Command To Confirm
That Hard Disk Drives Are Active
The probe-scsi command transmits an inquiry to SCSI devices connected to the
system's internal SCSI interface. If a SCSI device is connected and active, the
command displays the unit number, device type, and manufacturer name for that
device.
FIGURE 10-2
ok probe-scsi
Target 0
Unit 0
Target 1
Unit 0
The probe-scsi-all command transmits an inquiry to all SCSI devices connected
to both the system's internal and its external SCSI interfaces.
sample output from a Sun Fire V120 with no externally connected SCSI devices but
containing two 36 GB Hard Disk Drives, both of them active.
FIGURE 10-3
ok probe-scsi-all
/pci@1f,0/pci@1/scsi@8,1
/pci@1f,0/pci@1/scsi@8
Target 0
Unit 0
Target 1
Unit 0
10-8
Sun Fire V120 and Netra 120 Server User's Guide • December 2001
probe-scsi Output Message
Disk
SEAGATE ST336605LSUN36G 4207
Disk
SEAGATE ST336605LSUN36G 0136
probe-scsi-all Output Message
Disk
SEAGATE ST336605LSUN36G 4207
Disk
SEAGATE ST336605LSUN36G 0136
shows
FIGURE 10-3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sun fire v120

Table of Contents