November 2008
C-10 CHECK THE ELECTRIC CABLES
Every month, do a random check of the electrical cables
to be sure they are not damaged. In particular, we
recommend checking the cables located near moving
mechanical parts as they could rub against such parts
and get damaged.
CAUTION
Replace any worn cables immediately before using
the machine again.
Document 57.0009.0427
A
A
A
GTH-4017EX GTH-4514EX GTH-4013EX
Section 4 - Maintenance Procedures
C-11 CHECK THE WEAR OF THE SLIDING PADS
OF THE BOOM SECTIONS
Any boom section is fitted with adjustable pads located
on the four sides of the profile. These pads are secured
to both fixed and mobile part of every section.
All pads can be adjusted by the special shims not supplied
by GENIE.
CAUTION
Pads must compulsorily be replaced if the residual
thickness of the plastic layer with respect to the iron
bush fixing the block is equal or inferior to 1 mm.
Max. wearing thickness
TABLE C
Minimum 1 mm
39