Section 2 - Technical Specification
TECHNICAL SPECIFICATION
LIST OF THE DLE PARAMETERS
Winscope Name
00
C1cellaVuoto
01
C1cellaCarico
02
C1cellaMin
03
C1cellaMax
04
C2cellaVuoto
05
C2cellaCarico
06
C2cellaMin
07
C2cellaMax
08
Filter
09
paCellaUnica
10
Celle_MaxDelta
11
SpanForche
12
SpanNavicella
13
DeltaSpanGomme
14
OffSet0
15
OffSet1
16
paIsteresiSblocco
17
paRitardoSblocco
32
Description
Value saved in analog channel 1 - calibration with unloaded
machine (best setting around 700).
Value saved in analog channel 1 - calibration with loaded machine
(best setting around 300).
Min admissible value for analog channel 1 reading (if actual value
is below: alarm 2) (value set at 10 roughly).
Max admissible value for analog channel 1 reading (if actual value
is above: alarm 2) (value set at 1010).
Value save in analog channel 2 - calibration with unloaded machine
(best setting around 300).
Value save in analog channel 2 - calibration with loaded machine (best
setting around 700).
Min admissible value for analog channel 2 reading (if actual value is
above: alarm 3)(value set at about 10).
Max admissible value for analog channel 2 reading (if actual value is
above: alarm 3) (value set at about 1010).
Number of filter samples, with mobile mean. Load cell reading. Max
5.
Sets to 1 automatically (during the machine selection) when the DLE
is used in single channel mode.
Max admissible delta between readings of analog channels 1 and 2,
expressed as a %, default 10 (current 20).
Limiter intervention percentage in case of work with stabilised
machine and forks. Default: 100 (as per calibration).
Limiter intervention percentage in case of work with stabilised machine
and platform (changed by the relevant procedure during calibration).
When the platform is selected, the limiter uses this % (default 110%
- load increase of 10%) instead of the SpanForche datum (current
value 125).
Limiter intervention percentage in case of work with non-stabilised
machine (changed by the relevant procedure during calibration).
% value that adds to the calibration with forks and outriggers
(SpanForche).
Command given to the digital potentiometer for cell 1 (value
from 0 to 255) to set the reading scale during calibration with
unloaded machine to a certain pre-set value (about 900 bit ADC
- C1cellaVuoto) (about 700).
Command given to the digital potentiometer for cell 2 (value from 0 to
255) to set the reading scale during calibration with unloaded machine
to a certain pre-set value (about 200 bit ADC - C2cellaVuoto) (about
300).
Load % for the reset of the movements once the block condition
has been rectified. (default 5% = 95%).
Value expressed in tenths of second corresponding to the time
that must elapse between the block condition and the movement
reset (default 10 = 1 second).
GTH-4017EX GTH-4514EX GTH-4013EX
November 2008
Document 57.0009.0427