Terex Genie GTH-4017 EX Service Manual page 60

Table of Contents

Advertisement

Section 2 - Technical Specification
TECHNICAL SPECIFICATION
To get acces to the
INCHING
select:
P
arameter Functions (10).
Inputs.
Inching.
Set Defaults.
Inside the window "calibrate inch Potentiometer"
select the value 1 (see image 11).
F4.
PRESS
Inside the window "calibrate inch Potentiometer"
select the value 0 (see image 11).
F4.
PRESS
select the Setup Status menu (see image 12).
The system recognizes the calibration minimum
value automatically (for example, Min Value 1038-
image 12).
Step down the brake pedal until "calibration
complited" appears (see image 13), with the
maximum calibrate inching value - Max Value
7790.
To finish the calibration procedure, press "Stop
logging" or F6 (see image 14).
The machine can work.
38
from
PARAMETERS FUNCTIONS
10
GTH-4017EX GTH-4514EX GTH-4013EX
November 2008
11
12
13
14
Document 57.0009.0427