Section 2 - Technical Specification
TECHNICAL SPECIFICATION
To get acces to the
INCHING
select:
•
P
arameter Functions (10).
•
Inputs.
•
Inching.
•
Set Defaults.
•
Inside the window "calibrate inch Potentiometer"
select the value 1 (see image 11).
•
F4.
PRESS
•
Inside the window "calibrate inch Potentiometer"
select the value 0 (see image 11).
•
F4.
PRESS
•
select the Setup Status menu (see image 12).
•
The system recognizes the calibration minimum
value automatically (for example, Min Value 1038-
image 12).
•
Step down the brake pedal until "calibration
complited" appears (see image 13), with the
maximum calibrate inching value - Max Value
7790.
•
To finish the calibration procedure, press "Stop
logging" or F6 (see image 14).
•
The machine can work.