Terex Genie GTH-4017 EX Service Manual page 55

Table of Contents

Advertisement

November 2008
20
C1NavicellaVuoto
21
C1NavicellaCarico
22
C2NavicellaVuoto
23
C2NavicellaCarico
24
CurMacchina
28
VersioneSW
29
WPsum
LIST OF THE DLE VARIABLES
Winscope Name
05
PCorder
10
C1swl
13
C1adcFiltro
Document 57.0009.0427
Parameters 20, 21, 22 and 23 are usually equivalent to parameters
0, 1, 4 and 5. They shall be used for a new calibration of the platform
not depending on the proportional % calibration done with the forks.
These parameters only apply to the platform. Value saved in analog
channel 1 during calibration with empty machine.
Value saved in analog channel 1 during calibration with loaded
machine.
Value saved in analog channel 2 during calibration with empty
machine.
Value saved in analog channel 2 during calibration with loaded
machine.
Machine selected on point "0" of the calibration.
Software version.
Parameters CHECKSUM used by the safety functions.
Default
0
GTH-4017EX GTH-4514EX GTH-4013EX
Section 2 - Technical Specification
Description
You can save changes effected to the
parameters by setting this variable to "1". The
variable will return to 0 once the value has
been saved.
Load percentage of cell 1 (0% = calibration
without load; 100% = calibration under load).
Current value of cell 1 (analog, converted into
bits 0 - 1023).
TECHNICAL SPECIFICATION
33