Renewing The Slide Pads Of The Telescopic Boom Gth-4017Ex Gth-4514Ex - Terex Genie GTH-4017 EX Service Manual

Table of Contents

Advertisement

November 2008
Renewing the slide pads of the telescopic
Procedure:
boom GTH-4017EX GTH-4514EX
ADJUSTING THE PLAY WITH SHIMS
If the play between the boom sections is too great (2
mm or more), proceed in shimming the guide pads
of the boom sections.
Usually, the guide pads subject to premature wear
are:
• front bottom pads of the first, second and third
section
• rear top pads of the second, third and fourth
section
Proceed as follows:
1 Lower the boom to the ground and ensure the
telescope is fully retracted.
2 With a thickness gauge, check the play of all
pads.
After adjustment, the minimum play in the
narrowest point must be: 0,5÷1 mm.
3 Measure the thickness of the slide pads. The
value of the bottom pads of the fixed section and
of the top pads of the telescope must be at least
13 mm. For the remaining pads, the minimum
thickness must never be less than 9 mm.
4 If the thickness reaches the minimum value, renew
the pads before adjusting the residual play with
some shims.
5 Remove the fixing screws from the pads and
position as many shims as necessary to reach
the normal thickness value.
Document 57.0009.0427
GTH-4017EX GTH-4514EX GTH-4013 EX
012
Table:
GTH-4017EX
GTH-4514EX
GTH-4013EX
Standard tools
Thickn. 1÷2 mm
if needed
16
Section 7 - Repair Procedures
TABLE
Hours Min.
1
200
60
100
70
15
10
012
-
30
1
40
37

Advertisement

Table of Contents
loading

This manual is also suitable for:

Genie gth-4514 exGenie gth-4013 ex192961928619266

Table of Contents