Check The Tightening Of The Engine Fixing Screws - Terex Genie GTH-4017 EX Service Manual

Table of Contents

Advertisement

November 2008
4.6
TABLE D PROCEDURES
D-1
VISUALLY CHECK THE SMOKE QUANTITY
EVACUATED FROM THE ENGINE EXHAUST
To check the quantity of smoke evacuated from the engine
exhaust, proceed as follows:
-
Start the engine of the machine.
-
Wait for a few minutes so the engine can warm up
correctly.
-
Visually check that the amount of smoke coming
out of the exhaust is normal; repeat the check while
accelerating the engine.
CAUTION
Do this check outdoors or use an adequate smoke
extraction system.
NOTICE
In case of excess smoke, strictly obey the instruc-
tions provided in the relevant Use and maintenance
manual enclosed with the technical literature of the
machine.
Document 57.0009.0427
GTH-4017EX GTH-4514EX GTH-4013EX
Section 4 - Maintenance Procedures
D-2
CHECK THE TIGHTENING OF THE ENGINE
FIXING SCREWS
Every 6 months, check that the screws fixing the engine
to the machine chassis are tight.
For this operation, use a torque wrench and tighten the
screws to a torque of 146 Nm.
TABLE D
GTH 4013 EX
GTH 4017 EX
GTH 4514 EX
45

Advertisement

Table of Contents
loading

This manual is also suitable for:

Genie gth-4514 exGenie gth-4013 ex192961928619266

Table of Contents