FAULT TABLE "A"
Error code
15
19
23
27
31
35
39
70
SAFE-Mode: the machine stops and restarts only when
the panel is switched off and on again, after eliminating
the detected problem.
LIMITED-Mode: the machine moves adjusting the pump
but without controlling the engine; therefore, it moves at
limited speed.
Image 15: connections of the check transmission control
unit.
Image 16: functional scheme of the transmission. The
following elements are not used in the present system:
Creeper drive
Creeper drive switch.
PPU motor
Brake pressure defeat
Parking brake
Document 57.0009.0427
Error description
Battery Voltage or Sensor Voltage Error
Pump Current Forward EV
Pump Current Reverse EV
Motor Current EV
Diesel Engine Speed RPM
FNR Shortcut Neutral-Reverse
Inching
CAN Line
GTH-4017EX GTH-4514EX GTH-4013EX
Section 2 - Technical Specification
Connector 2
Pin
Controller Function
C2-P1
Mode switch
C2-P2
DIN/AIN/FreqIN
C2-P3
Forward
solenoid valve hydrostatic pump
C2-P4
Reverse solenoid valve hydrostatic pump
C2-P5
warning error lamp
C2-P6
Reverse gear buzzer and lamp
C2-P7
Hydrostatic motor displacement
C2-P8
-
C2-P9
Brake light
C2-P10 -
C2-P11 Power supply + 12 volts
C2-P12 Power supply + 12 volts
Connector 1
Pin
Controller Function
C1-P1
Power ground -
C1-P2
Power supply + 12 volts
C1-P3
CAN + (H)
C1-P4
CAN - (L)
C1-P5
AIN/CAN shield
C1-P6
Forward
C1-P7
Reverse
C1-P8
Power +5 Volts inch. pedal
C1-P9
Ground - inch. pedal
C1-P10 Inch. pedal segnal
C1-P11 -
C1-P12 Engine rpm
TECHNICAL SPECIFICATION
Machine state
SAFE Mode
SAFE Mode
SAFE Mode
SAFE Mode
SAFE Mode
LIMITED Mode
SAFE Mode
LIMITED Mode
Connector 2
'B' key (black)
12
11
10
9
8
7
Connector 1
'A' key (grey)
12
11
10
9
8
7
15
1
2
3
4
5
6
1
2
3
4
5
6
39