November 2008
FAULT TABLE "A"
Error code
15
19
23
27
31
35
39
70
SAFE-Mode: the machine stops and restarts only when
the panel is switched off and on again, after eliminating
the detected problem.
LIMITED-Mode: the machine moves adjusting the pump
but without controlling the engine; therefore, it moves at
limited speed.
Image 15: connections of the check transmission control
unit.
Image 16: functional scheme of the transmission. The
following elements are not used in the present system:
•
Creeper drive
•
Creeper drive switch.
•
PPU motor
•
Brake pressure defeat
•
Parking brake
Document 57.0009.0427
Error description
Battery Voltage or Sensor Voltage Error
Pump Current Forward EV
Pump Current Reverse EV
Motor Current EV
Diesel Engine Speed RPM
FNR Shortcut Neutral-Reverse
Inching
CAN Line
GTH-4017EX GTH-4514EX GTH-4013EX
Section 2 - Technical Specification
Connector 2
Pin
Controller Function
C2-P1
Mode switch
C2-P2
DIN/AIN/FreqIN
C2-P3
Forward
solenoid valve hydrostatic pump
C2-P4
Reverse solenoid valve hydrostatic pump
C2-P5
warning error lamp
C2-P6
Reverse gear buzzer and lamp
C2-P7
Hydrostatic motor displacement
C2-P8
-
C2-P9
Brake light
C2-P10 -
C2-P11 Power supply + 12 volts
C2-P12 Power supply + 12 volts
Connector 1
Pin
Controller Function
C1-P1
Power ground -
C1-P2
Power supply + 12 volts
C1-P3
CAN + (H)
C1-P4
CAN - (L)
C1-P5
AIN/CAN shield
C1-P6
Forward
C1-P7
Reverse
C1-P8
Power +5 Volts inch. pedal
C1-P9
Ground - inch. pedal
C1-P10 Inch. pedal segnal
C1-P11 -
C1-P12 Engine rpm
TECHNICAL SPECIFICATION
Machine state
SAFE Mode
SAFE Mode
SAFE Mode
SAFE Mode
SAFE Mode
LIMITED Mode
SAFE Mode
LIMITED Mode
Connector 2
'B' key (black)
12
11
10
9
8
7
Connector 1
'A' key (grey)
12
11
10
9
8
7
15
1
2
3
4
5
6
1
2
3
4
5
6
39