Advice To Renew Flexible Hoses - Terex Genie GTH-4017 EX Service Manual

Table of Contents

Advertisement

Section 2 - Technical Specification
TECHNICAL SPECIFICATION
2.17

ADVICE TO RENEW FLEXIBLE HOSES

PROTECT THE
ENVIRONMENT
Before disconnecting a hydraulic pipe, place
containers of suitable size underneath to prevent
oil spillage.
CAUTION
Plug all disconnected parts to prevent dust or
impurities from entering the circuit. They can cause
serious damage.
DANGER
Before disconnecting the hydraulic pipe, check that
there is no residual pressure. In case, eliminate the
pressure operating the control levers with the engine
stopped. In any case, disconnect the hydraulic pipe
with extreme caution and always wear suitable
personal protection equipment -e.g. goggles, gloves,
facial screen, etc. Wrap up the end of the pipe to be
disconnected with some rags and slowly loosen
the pipe connector so that air comes out as slow as
possible.
Useful advice for mounting flexible hoses:
NO
NO
8
NO
YES
YES
GTH-4017EX GTH-4514EX GTH-4013EX
1
Before disconnecting or refitting a flexible hose,
carefully clean the area all around.
2
Blow some compressed air to remove any impurity.
3
For an easier renewal of the hoses, whose run is not
clearly visible, proceed as follows:
disconnect the hose to be replaced from both
sides
tie a cord to one end of the hose
remove the hose pulling the cord until it comes out
completely
untie the cord and tie it to the new hose, make sure
the hose has a cork to avoid dust and impurity in
the circuit
pull the cord from the other side to refit the hose until
reaching the connecting point to the line.
YES
NO
YES
November 2008
NO
YES
Document 57.0009.0427