November 2008
Click on
•
STATUS
•
ELECTRICAL
to open the ELECTRICAL STATUS window and to find
some possible mistakes on the system (image 7). The
signal of ERROR is present on the instrument panel
too.
See the list of errors at page 39 in the "FAULT TABLE A".
Select
PARAMETERS FUNCTIONS
Select
•
Allparameters V168 (8).
•
Press F2 to ensure the present parameters are
uploaded on the control unit.
•
Click on "import values from a parameter data
filer".
•
Select the right
(401701 o 401301)
FILE
•
Press F4 to up-load the parameters on the control
unit.
•
The control unit can work.
•
Perform the pedal inching calibration (see next
chapter).
Document 57.0009.0427
ERROR
Short shimmering
Long blinks: tens (3)
Short blinks: units (5)
ERROR CODE
35
to check the parameters.
GTH-4017EX GTH-4514EX GTH-4013EX
Section 2 - Technical Specification
TECHNICAL SPECIFICATION
7
8
9
37