Check The Efficency Of The Overload Warning System - Terex Genie GTH-4017 EX Service Manual

Table of Contents

Advertisement

November 2008
Section 4 - Maintenance Procedures
TABLE A
A-20 CHECK THE EFFICENCY OF THE OVERLOAD
WARNING SYSTEM
When the machine starts, the DLE system executes a
check.
2
When power is turned on, the DLE load limiting system
runs a self-test. In the case of troubles, LED's 5, 8 and
10 start flashing, the buzzer sounds, an error code is
shown on the display 2 and the machine enters the
alarm mode and cannot be operated.
The meaning of the error messages is shown in Section 2.
To do a manual check, it will be enough to load a
known weight on the forks and extend the boom fully
5
8
10
in zero position until the DLE system enters in alarm.
Then, using a measure check the distance is in the area
indicated in the load chart inside the cab (see below)
In case of defects, make a diagnosis and adjust the
system.
GTH-4013 EX - SX
GTH-4514 EX
GTH-4017 EX
09.4618.0898
25
Document 57.0009.0427
GTH-4017EX GTH-4514EX GTH-4013EX