Section 2 - Technical Specification
TECHNICAL SPECIFICATION
2.22

DLE SYSTEM

INSTALLATION OF THE EXTENSIMETRIC CELL
1
= strain cage
2
= washer ø 10
3
= fixing screw M10x40 cl. 10.9
machine side
(output extensometer rope)
rear axle plane
ground and unpainted area for
24
2
wheel side
resin side view
strain cage support
GTH-4017EX GTH-4514EX GTH-4013EX
To avoid damaging strain cage and to get maximum
results, proceed as follows:
1 - PREPARATION:
-
Thoroughly clean whole tightening system, especially
the ground and unpainted area A of rear axle.
2 - ASSEMBLY:
3
-
Apply the strain cage B with its resinated side
facing the axle and holding the cable(s) toward the
machine.
-
Tighten the two screws C with a torque wrench at 70
Nm.
-
Mark the position of the screws with paint in order to
make possible loosening visible to the eye.
1
B
November 2008
C
A
Document 57.0009.0427