November 2008
DISPLAY
0
1
2
3
F
Document 57.0009.0427
FUNCTION
The LED bar indicates the type of machine in use:
1 LED on -GTH 4013EX - GTH 4017EX - GTH 4017EX
To select the machine to be calibrated press
press
to reduce the number of LED's lit.
If you are doing the first calibration, press
parameters of the selected machine.
If you are re-calibrating the instrument, directly jump to point 1.
Press
to proceed to the next point (1).
Lower the outriggers to the ground, fully retract the boom holding it slightly above the
horizontal with respect to the ground. DON'T lift loads.
Press
to confirm the EMPTY calibration of the machine. The audible alarm will sound
to confirm the command has been executed.
Press
to proceed to the next point (2).
With outriggers down, place a load on the forks with a known weight, extend the boom
while holding it horizontal till reaching the overturning moment. The overturning distance
is from the front part of the wheels to the center of the load. (see the diagram inside the
cab).
Press
to confirm the LOADED calibration of the machine and check that the alarm
triggers. The audible alarm will sound to confirm the command has been executed. Move
the boom fully in while holding the same in the horizontal position.
Press
to proceed to the next point (3).
With outriggers up, place a load on the forks with a known weight, extend the boom while
holding it horizontal till reaching the overturning moment. The overturning distance is
from the front part of the wheels to the center of the load. (see the diagram inside the
cab).
Press some times
them; at the end, all LED's are on from left to right, except the red last one. To do this,
we recommend starting with the LED's bar on the green area and then press to increase
the number of LED's lit.
The procedure is saved automatically
Press some times
Press
to exit calibration and to SAVE the changes made (the audible alarm sounds
and the LED's come on to confirm that data have been saved).
The limiter is no longer in the calibration mode. The LED
You should turn the machine off and then on again to eliminate any alarm messages.
Starting to work.
GTH-4017EX GTH-4514EX GTH-4013EX
to switch off the LED's of the load and press
to arrive to the point (F).
Section 2 - Technical Specification
TECHNICAL SPECIFICATION
to increase the number of LED's lit or
to reset the system and load the default
is not lit fixed any more.
to switch on
27