Section 2 - Technical Specification
TECHNICAL SPECIFICATION
1
2
4
5
6
- Description of the controls:
1 Calibration selection button
2 Display
3 Stability indicator with LED-bar
4 Green light - power OK
5 Yellow light - calibration mode
6 Calibration confirmation button
7 Not used
8 Red light - outrigger position
9 Buzzer ON/OFF pushbutton
10 Red light - overload pre-alarm/alarm
The digit on display 2 shows the selected attachment.
The user can choose among:
0: Generic
1: Platform
The system recognises the attachment fitted to the
machine automatically.
After calibrating, using different weights, check the
correspondece with the load charts (lenghts from the
front tyres to the center of the weight on the fork).
26
3
10
9
7
8
GTH-4017EX GTH-4514EX GTH-4013EX
CALIBRATING THE DLE SYSTEM
NOTICE
During the calibration mode the limiter device
doesn't block any manoeuvres so the calibration
can be done.
With outriggers, calibrate the
load and with load and outriggers fully at
ground.
The calibration of the machine should be done
after a few minutes of use, in other words with
the machine "warm".
- Enter the calibration mode:
Within 5 seconds from when the instrument is activated
(even if the display is still off) you should press the
keys on the front panel in the right sequence.
Belowe, the push buttons and their mean:
Press
to enter number 0
Press
to enter number1
Press
to confirm the sequence entered.
The access code currently used is 1001. Therefore
you should enter the following sequence:
1
0
0
If the sequence is correct the confirmation of the
instrument functioning in the calibration mode is
given by the LED near
light.
The display shows a number that ISN'T blinking,
starting from "0".