Water-Oil Cooler Disassembly - Terex Genie GTH-4017 EX Service Manual

Table of Contents

Advertisement

November 2008

Water-oil cooler disassembly

Procedure:
Operation:
PROTECT THE
ENVIRONMENT
Before disconnecting the hydraulic piping, place
containers of suitable size underneath to prevent
oil spillage.
CAUTION
Carefully clean the area around the piping to be
disconnected, plug all disconnected parts with
connectors, clothes or adhesive tape to prevent
dust or impurities from entering the circuit. They
can cause serious damage.
1 Open the carter and disconnect the two battery
terminals using a 13mm wrench; then, remove the
screws fixing the fuse box to carter using a 4mm
Allen wrench and a 10mm combination wrench.
2 Install a handler under the carter and remove the
six screws fixing the lower carter to the chassis
using two 17mm wrenches; then remove the
lower carter.
3 Empty the cooler opening the special cocks.
4 Disconnect the two hydraulic oil hoses from the
cooler using a 41mm wrench.
5 Disconnect the water and air pipes from/to the
thermal motor loosening the hose-clamps with
a screwdriver.
Document 57.0009.0427
GTH-4017EX GTH-4514EX GTH-4013 EX
009
Table:
GTH-4017EX
GTH-4514EX
GTH-4013EX
Standard tools
2
4
5
3
Section 7 - Repair Procedures
TABLE
24
Hours Min.
2
009
-
1
27