Problems
The hour-meter doesn't work.
The display of the overload
warning
system
turned on.
The back-up horn doesn't work
The hydraulic oil filter restriction
indicator light doesn't work.
Document 57.0009.0427
Causes
Hour-meter damaged.
Alternator A1 damaged.
Problem of the wiring line.
10A F25 fuse blown.
cannot
be
DLE display damaged.
Problem of the wiring line.
Back-up horn damaged.
Problem of the wiring line.
Bulb damaged.
Indicator light on dashboard.
Problem of the wiring line.
GTH-4017EX GTH-4514EX GTH-4013EX
Section 5 - Problems-Causes-Solutions
-
PROBLEMS
CAUSES
Solutions
Check the hour-meter and replace
if necessary.
Check the alternator and replace if
necessary.
Check the wiring for continuity.
Check the fuse and replace if
necessary.
Change the DLE.
Check the wiring for continuity.
Check the efficiency of the back-up
horn and replace, if necessary.
Check the wiring for continuity.
Check the efficiency of the bulb and
replace, if necessary.
Check the indicator light.
Check the wiring for continuity.
-