Maintenance Schedule - Stratasys FORTUS 360mc Manual

Hide thumbs Also See for FORTUS 360mc:
Table of Contents

Advertisement

FORTUS 360mc/400mc and FDM 360mc/400mc User Guide

Maintenance Schedule

Maintenance tasks must be performed on a regular basis in order to
maintain optimal system operation.
maintenance schedule. Detailed instructions for each task make up the rest
of this chapter.
Warning:
removing any of the access panels.
Warning: Due to the UPS, High voltage is present in the
system when the power cord is unplugged.
Warning: Always wear proper heat protective clothing when
working inside the oven.
Daily Weekly Quarterly
X
X
X
X
Always power down and unplug the system before
Table 7-1: Maintenance Schedule
"Clean the Platen" on page 7-4
"Empty the Purge Waste Bucket" on page 7-4
"Vacuum the Build Envelope" on page 7-5
"Clean/Inspect Tip Wipe Assembly" on page 7-5
"Inspect the Platen O-Ring" on page 7-8
X
"Clean the Vacuum System In-Line Filter and Jar" on
X
page 7-8
"Clean the Tip Sensor Plunger" on page 7-9
X
Table 7-1
outlines the general
Maintenance Task
7-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fortus 400mc

Table of Contents