Screen Symbols; Powering Up The System - Stratasys FORTUS 360mc Manual

Hide thumbs Also See for FORTUS 360mc:
Table of Contents

Advertisement

FORTUS 360mc/400mc and FDM 360mc/400mc User Guide

Screen Symbols

The following symbols are used in the menu displays.
Symbol
<E>
<E>..
".."
":"
" = "
" * "
(!)
" ! ! "
C

Powering Up the System

1.
Turn the system ON by pressing the flashing green button
• The Power up message is displayed.
2.
If there is a completed part in the system, select Unlock Door <E>, and
remove the part from the system. Install a new build sheet and close
the door.
3.
Verify that the air pressure gauge (located in the canister bay) reads
36-40 psi. (External air should be 48-52 psi.)
4.
Select
AutoHome XYZ
• The system will find the home position for the X, Y, and Z axes.
This must be done before any parts can be built.
5.
If the system has been powered down long enough for the oven to
cool, allow the oven to oven to heat and stabilize for at least four hours
before performing system calibrations or part build.
Description
Push ENTER to execute the command line. (The cursor ">"
must be on the same line.)
Push ENTER to execute command line. Also pushes you
into another menu.
Tells you that this line is a menu change. It implies that you
may return without executing a command.
Indicates that this command line value changes.
Value displayed in the command line is user changeable.
Indicates that this is a comment line. (Symbol is shown at
beginning of line.)
Displayed at the end of a line in the job queue or sample
queue. Indicates insufficient material available; wrong
type of material loaded; or wrong tip installed. Select line
and press <.> (Dot key) to show details.
Displayed at start of Warning message.
Temperatures are displayed in Celsius only.
and press ENTER.
(Figure
4-1).
4-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fortus 400mc