Moving the System

If you need to move the system to a different location, a specific sequence of
steps must be followed.
1.
Unload material filament from the liquefiers.
from the Liquefier Tips" on
2.
Remove the material canisters. See
13.
3.
Lower the Z stage to the bottom of its travel. See
to Bottom of Travel" on
4.
Shut down power to the system. See
page 4-4.
Warning: due to the UPS, High voltage is present in the
system with the power cord unplugged.
Caution: Before unplugging the system always make sure the
oven is cool to avoid blowing the oven thermal cut-out fuses.
5.
Unplug the power cable from the power source.
6.
Secure the Z stage:
A.
Remove all side panels on the system.
B.
Grasp the Z stage drive belt and the lower Z stage until the end
plates rest on the lower hard stops.
C.
On the left and right side of the system, wrap a large wire tie
around the end plate and the lower bearing mount plate, see
Figure
• Make sure the wire tie is tight.
page 4-36.
2-5.
Figure 2-5: Securing the Z Stage
page 4-12.
"Removing Canisters" on page 4-
"Powering Down the System" on
See"Unloading Material
"Moving the Z Stage
End Plate
Tie Wrap
Bearing Mount
Plate
2-5