Auto Z Stage Zero Calibration - Manual Start

Note: An Auto Z Stage Zero Calibration must be performed
after running
procedure to manually initiate the calibration.
Note: Perform an Autohome XYZ before Z Stage Zero
Calibration (Operator Control > Calibrate > AutoHome XYZ).
1.
Make sure a build sheet is installed and verify that vacuum is present.
2.
Run the Auto Z Stage Zero Calibration
A.
From the Main Menu select Operator Control and press Enter.
Build Job..
>Operator Control..
Modeler Status..
Maintenance..
B.
Select Calibrate and press Enter.
Unlock Door <E>
Load/Unload Mtl..
Change Tips/Mtl..
>Calibrate..
C.
Select Set Z Stage Zero and press Enter.
>Set Z Stage Zero..
AutoCal Tips <E>
Tip Offset Value..
AutoHome XYZ <E>
D.
Select Auto Z Zero Calibrate and press Enter.
Set Manual Z Stage Zero <E>
Modify Current Z Zero..
>Auto Z Zero Calibrate <E>
E.
The system performs an Auto Z Stage Zero Calibration. If Auto Z
Stage Zero Calibration fails, perform
page 6-6.