System Status
The user interface can be used to display each of the following:
• Temperature Status
• Odometer Status
• Material Status
• System Software Version
• Other System Information
Temperature Status
To view the current and setpoint temperatures for the oven and liquefiers:
1.
From the Main Menu select
Build Job..
Operator Control..
>Modeler Status..
Maintenance..
2.
Select
Temperatures
temperatures are displayed
>Temperatures..
Material Status..
Tip Status..
Machine State
*
* Oven:78° C / 80° C
* Model:198° C / 200° C
* Support:301° C / 300° C
Odometer Status
The system tracks and displays the total amount of material extruded through
a liquefier tip since it was last replaced. To view the tip odometers:
1.
From the Main Menu select
Build Job..
Operator Control..
>Modeler Status..
Maintenance..
4-32
FORTUS 360mc/400mc and FDM 360mc/400mc User Guide
Modeler Status
|*Tips: Model T16
|*
and press ENTER. The current and setpoint
Current Setpoint
Modeler Status
|*Tips: Model T16
|*
and press ENTER.
Support T16
and press ENTER.
Support T16