Pausing or Aborting a Job

1.
During a part build, the system can be paused:
A.
Automatically (canister runs out of material, failure detected, etc.)
Note: If an automatic pause occurs, press the HELP key to
view the cause.
B.
Manually - press and hold the PAUSE key on the operator panel
for 2 - 3 seconds.
2.
When the system is directed to pause:
A.
The current tool path is completed.
B.
The Z stage is lowered slightly.
C.
The head is parked.
D.
The user display will change to indicate the paused condition.
*
Job: clip4
>Resume Build <E>
Modeler Status..
Operator Control..
3.
From Pause mode, you can make the following selections:
Resume Build
door, top door, or top hood is open, or if vacuum is not present, the
screen will display
Modeler Status
Operator Control
materials (including load/unload and canister removal/
installation), move the head, or move the Z stage.
Abort Job
Auto-Cool
current job only. See
more information.
4-10
FORTUS 360mc/400mc and FDM 360mc/400mc User Guide
| Abort Job..
| Auto Cool:
- the system resumes building the part. If the oven
Can't Resume (Help)
- View the Job Status and Canister Status.
- Unlock the door/hood, clean tips, change
- Aborts the current job.
- The auto-cool down setting can be changed for the
"Oven Temperature Control" on page 4-35