Material Status - Stratasys FORTUS 360mc Manual

Hide thumbs Also See for FORTUS 360mc:
Table of Contents

Advertisement

FORTUS 360mc/400mc and FDM 360mc/400mc User Guide
2.
Select
Tip Status
displayed.
Temperatures..

Material Status..

>Tip Status..
Machine State
*
Mat'l amount
*Model tip
*Support tip :
*Tips: Model <T16>
Material Status
You can find the current status of each material canister.
1.
From the Main Menu select
Build Job..
Operator Control..
>Modeler Status..
Maintenance..
2.
Select
Material Status
shown..
Temperatures..
>Material Status..
Tip Status..
Machine State
** Model
*
Model
** Support 1:
*
Support 2:
and press ENTER. The current status of the tips is
:
13.0 in3
54.0 in3
Support <T16>..
Modeler Status
|*Tips: Model T16
|*
and press ENTER. All active canisters are
1:
PC
56.4
2:
PC_S
21.4
Remaining
Type of
Volume
Material
and press ENTER.
Support T16
in3
(Loaded)
in3
(None)
in3
(Loaded)
in3
(None)
Status of each: None, Ready,
Loaded, At Head, Empty,
Misloaded, No Read