Note: If a GFCI trips without pressing its test button with any type of load—test-load or normal operating load—plugged into its
corresponding receptacle, then there is a problem with the load or the connected circuit which must be checked and corrected by a
qualified electrician.

Genset shutdown

1
2
037-05-63-310B
Figure 57: Genset-Engine Shutdown
1. Switch the Rated/Idle switch (1) to idle (), CB1 will automatically trip due to under frequency. Allow the engine to idle
3 to 5 minutes to cool down before shutting it off after a full-load operation. This allows adequate cool down of engine
pistons, cylinders, bearings, and turbocharger components.
2. After the cool down period, move the genset Stop/Run/Start switch (2) to stop (
).
69
037-08OP-002D-01
S/N CB50600021 – UP (Weld-deck)