Before Starting Genset-Engine

Make a thorough walk-around inspection and specific module checks:

Welding deck

1. Fully extend the catwalks all around the deck.
2. Check for obvious signs of damage, lose bolts, lose equipment, and foreign objects or debris on and under the deck.

Welder Doghouse

1. Open up the folding door on the Doghouse and slide it all the way back, pushing it firmly into its spring latch; ensure
that it latches securely.
2. Ensure that the two slide-out trays holding the welding machines are securely latched in the retraced position.
3. Check that the rubber isolators on the Doghouse are undamaged and that all the bolts are tight.

Genset

2
1
3
4
5
037-05-50-163A
037-05-50-164A
Figure 45: Genset prestart checks
1. The Genset is fuelled by the carrier's fuel tank, check that there is adequate fuel to run the Genset and carrier for the
intended operation (a full tank per day).
2. Check all of the louvers on the Genset compartment to ensure that they are free of obstructions and debris.
3. Open the main service doors on the right hand side (genset side) and check the general appearance of the Genset.
Perform a visual inspection, checking for obvious signs of damaged or loose components and wires, loose or worn radiator
hoses, worn or damaged isolators, etc. Check that there are no foreign objects such as rags, tools, etc., present in the
compartment. Check the rubber isolators on the feet of the engine and alternator, and at the base of the radiator are
undamaged and that all the bolts are tight. Check that the radiator cooling fins are free from dirt and debris, blow out with
compressed air if necessary. Note: The access panels on the left or turbo side of the engine should be removed to perform a
complete visual inspection.
4. Check that the Engine Harness is firmly secured to the Engine Control Module (ECM) (1), tighten the centre holding-
screw if required. Note: Do not start the genset engine if the harness is not connected to the ECM as damage to the engine
may result.
59
037-08OP-002D-01
S/N CB50600021 – UP (Weld-deck)