Battery Disconnect Switch

The battery disconnect switch is in the genset enclosure behind the main door on the right (fuel pump) side of the weld-deck.
Figure 22: Battery Disconnect Switch
I
ON — Insert the battery disconnect switch key, and turn the battery disconnect switch key clockwise in order to activate
the electrical system. The switch must be ON before you start the engine.
O
OFF — Turn the battery disconnect switch key counter clockwise in order to shut off the entire electrical system.
NOTE: Ensure the Genset Stop/Run/Start Switch is off for at least 30 seconds before turning the battery disconnect switch to
OFF to allow proper engine control module (ECM) shut down.
The battery disconnect switch and the genset Stop/Run/Start Switch serve different functions. When the battery disconnect
switch is turned off, the entire electrical system is disabled. When only the engine start switch is turned off, the battery
remains connected to the electrical system.