Rated/Idle Switch

IDLE
With
rated/idle switch in this
position, the genset engine runs
at
an
idle
speed
approximately700 - 900 RPM.
Use this position for start-up,
warm-up, and during extended
periods of running with no load.
Note: Do not operate the engine
at idle for long periods with the
engine
coolant
temperature
below
the
minimum
recommended in the Cummins®
Operation
and
Maintenance
Manual QSB4.5 and QSB6.7
Engine (Bulletin 4021531); see
the appendices at the end of the
Weld-Deck
Operation
Maintenance
Manual,
Deck welding package CPW 125-
4-S2-4.
RATED — With the rated/idle switch in this position, the genset engine runs at full or rated speed; approximately
1500 RPM @ 50z, 1800 RPM @ 60 Hz. Use this position when working.
Note: The main breaker will only set when the genset rated/idle switch is in the RATED position.

Ether Starting Aid

Figure 27: Genset Ether Starting Aid
Ether Starting— At temperatures below 0°C (32°F), a metered amount of ether will be injected into the intake when
the ether starting aid button is released. Push and release the BLACK ether starting aid button while cranking the
engine. Refer to the Cold Weather Starting Below 0°C (32°F) with Ether Starting Aid section this manual for complete
operating instructions.