6.1.3 Nexstar Iii Error Code Table - Vanguard CPW 125-4-S Series Operation And Maintenance Manual

Weld-deck welding package
Table of Contents

Advertisement

6.1.3 NEXSTAR III ERROR CODE TABLE

Error Code
S1 CAN RX TO
Reception of a can message
timed out
S2 TEMP OUT OF
Outside of operating temperature
RANGE
- -40° c to 85° c
S16-S31 OUT X
When the output was activated,
OVER-CURRENT
a current of more than 3.5a was
ERR
being drawn.
S32-S47 OUT X
When the output was supposed
+VB SHORT
to be a ground, it had a positive
voltage.
S32-S47 OUT X –
When the output was supposed
VB SHORT
to be a positive voltage, it had a
ground.
A1 BOOM PSI
Lift cylinder pressure below 50
LOW
psi
A2 CW LIMIT
Crane has reached the limit of
rotation in the cw direction
A3. CCW LIMIT
Crane has reached the limit of
rotation in the ccw diretion
A4. TRK TILT
Truck angle exceeds 5.7
WARN
degrees or 10% slope
A5 TRK TILT
Truck angle exceeds 8.5
ALARM
degrees or 15% slope
A6. ANTI 2-BLOCK
Anti 2-block is activated. The
boom has contacted the
traveling block.
A7 90% LOAD
Reached 90% of rated capacity
WARN
A8. 100% LOAD
Reached 100% of rated capacity
ALARM
A9 SLOW ROTATE
Lift cylinder has exceeded 600
AC
psi
A10. BOM
Boom angle sensor signal failed
SENSOR ERR
A11 BOOM ANGLE
Angle sensor is out of range
RANGE
A12 BOOM PT
Boom pressure transducer error
ERR
A13 DIRTY FILTER
Filter is dirty if temperature of oil
is at least 100°
Cause
All outputs will be disabled
All outputs will be disabled
That output will be disabled
That output will be disabled
That output will be disabled
Disables all functions except boom up
and hoist down
Disables clockwise rotation
Disables counterclockwise rotation
All functions will only operate at 50% of
speed
Ll functions are disabled
Disables boom down, extend, and hoist
up
All functions will only operate at 50% of
speed
Disables boom down, extend, and hoist
up
Reduces rotation speed by 50%
All functions will only operate at 50% of
speed
Operates normally
All functions are disabled except boom
down and hoist down
Operates normally
Table 4. Error Code Table
Effect
24
Solution
Determine why messages are not
being received. When problem is
corrected the alarm will clear
Get temperature into acceptable
range and alarm will clear after 1
minute
Cycle power to receiver. If
problem continues. Find what
caused the overcurrent draw and
cycle power.
Determine the cause of the short.
Fix the cause and cycle power to
the receiver
Determine the cause of the short.
Fix the cause and cycle power to
the receiver
Hoist down load if applicalble.
Raise boom off any supports.
Alarm will clear once pressure in
cylinder is restored.
Rotate ccw to clear the error.
Once the switch is deactivated
the alarm will clear.
Rotate cw to clear the error.
Once the switch is deactivated
the alarm will clear.
Move vehicle to level ground
Move vehicle to level ground
Move load away from the boom
by either retracting, hoisting
down, or booming up. If there is
no load near the tip of the boom
check function of the bail
weldment, it must come into
contact with the switch plunger
under normal conditions
Reduce load to clear the alarm
Reduce the load by retracting the
boom, lowering the boo, or
raising the boom.
This is a safety feature that
prevents excessive swinging of
heavy loads. It will reset when
the load decreases and function
is deactivated.
Check connections to boom
angle sensor. Verify lights are on
at sensor base.
Boom angle sensor is mounted
incorrectly. Check the mounting.
The arrow should be facing the
tip of the crane.
Check connections to pressure
transducer located on the lift
cylinder. Check the wiring
harness for damage
Replace filter. Part number is
366823910

Advertisement

Table of Contents
loading

Related Products for Vanguard CPW 125-4-S Series