Hyundai HX130LCR Manual page 232

Hide thumbs Also See for HX130LCR:
Table of Contents

Advertisement

3. USER MODE SELECTION SYSTEM
Cluster
User mode
pilot lamp
1)
Engine speed, idle speed and pump power shift pressure can be adjusted and memorized in the
U-mode.
2)
LCD segment vs parameter setting
Step
Engine speed
(
)
1
2
3
4
5
6
7
8
9
10
※ Refer to the page 5-76.
Engine
ECM
User mode switch signal
CAN #2
Idle speed
(rpm)
1300
1400
1500
1100 (Auto decel)
1600
1700
1800
1900
2000
2050
2100
Main control valve
Main pump
Pilot pump
Pump power
shift EPPR
Drive signal
MCU
Accel dial signal
Power shift pressure
(rpm)
1000
1050
1130
1150
1180
1200
1230
1250
1280
5-5
Accel dial
Emergency
CN-16B
CN-16A
CN-16
Normal
130ZF5MS04
(bar)
0
3
6
9
12
16
20
26
32
38

Advertisement