2)
TEST PROCEDURE
(1)
Test 4 : Check electric current at EPPR
valve.
Disconnect connector CN-75 from EPPR
valve.
Insert the adapter to CN-75 and install
multimeter as figure.
Start engine.
Set S-mode and cancel auto decel
mode.
Position the multimodal dial at 10.
If rpm show approx 1750±50 rpm
disconnect one wire harness from EPPR
valve.
Check electric current at bucket circuit
relief position.
(2)
Test 5 : Check pressure at EPPR valve.
Remove plug and connect pressure
gauge as figure.
·Gauge capacity : 0 to 50 kgf/cm
Start engine.
Set S-mode and cancel auto decel
mode.
Position the multimodal dial at 10.
If rpm show approx 1750±50 rpm check
pressure at relief position of bucket
circuit by operating bucket control lever.
If pressure is not correct, adjust it.
After adjust, test the machine.
2
(0 to 725 psi)
6-43
Spec : 100~700 mA
Adapter(P/no.:21Q6-50410)
Multimeter
CN-75
Main pump
SPEC : 2~25 kgf/cm
(30~350 psi)
2
Pressure adjusting
screw locknut
CN-75
Valve casing
Main pump
EPPR valve
Valve casing
145ZF5MS21
Pilot pressure
supply line
EPPR valve
145ZF5MS22