Flow reset function
621 652
Large diameter
chamber
As the self pump delivery pressure P1 or the companion pump delivery pressure P2 decreases,
the compensating rod (623) is pushed back by the action of the springs (625 & 626) to rotate
lever 1 (612) around point E. Rotating of lever 1 causes the feedback lever (611) to rotate
around the fulcrum of point D and then the spool (652) to move to the left. As a result, port CL
opens a way to the tank port.
This causes the servo piston to move to the left and the pump's delivery rate to increase.
The movement of the servo piston is transmitted to the spool by the action of the feedback
mechanism to move it till the opening between the spool and sleeve is closed.
651
623
612 601
P1
CL
F
P2
P1
D
Servo piston
2-15
625
626
B(E)
897
875
611
Small diameter
chamber
140Z92RG04