Group 16 Fuel Warmer System - Hyundai HX130LCR Manual

Hide thumbs Also See for HX130LCR:
Table of Contents

Advertisement

GROUP 16 FUEL WARMER SYSTEM

1. SPECIFICATION
1)
Operating voltage : 24±4 V
2)
Power : 350±50 W
3)
Current : 15 A
2. OPERATION
1)
T h e c u r r e n t o f f u e l w a r m e r s y s t e m i s
automatically controlled without thermostat
according to fuel temperature.
2)
At the first state, the 15 A current flows to the fuel
warmer and engine may be started in 1~2
minutes.
3)
If the fuel starts to flow, ceramic-disk in the fuel
warmer heater senses the fuel temperature to
reduce the current as low as 1.5 A.
So, fuel is protected from overheating by this
mechanism.
3. ELECTRIC CIRCUIT
POWER RY
EM'CY STOP SW
V
5R
3L
CS-74B
2
1
MASTER SW
C ST
RMS
READER
GPS CONN
CN-231
8W
8R
FUSE BOX
ANTI-RESTART RY
2W
2W
CN-436
B
0,
I
IEC 58A
IEC 61A
GLOW BEEDBACK
I 0
H
PWR INPUT
ACC BR
H
GLOW GND
START KEY SW
IEC 57A
IEC 60A
GLOW COMMAND
MCU
5-94
Filter head &
fuel warmer
Prefilter
8W
1
8R
2
BEARHER
HEATER
CS-74
1
2
MASTER SW
90A
CN-95
8W
2
8W
1
CIRCUIT BREAKER
8R
2
8R
1
60A
CN-60
CR-1
60R
BATTERY
(12VX2)
BATT RY
CR-23
CN-45
M
2
M
1
B+
START RY
STARTER
CN-94
54
KEY IG
01
BATT+(A)
8
START REQUEST
27
START CTRL OUT -
53
START CTRL OUT +
0.75GrB
52
GLOW COMMAND
1
0.75V
22
GLOW FEED BACK
0.75B
2
0.75V
41
GLOW FEED GND
3
81
EXHAUST TEMP GND
6.0R
4
82
EXHAUST TEMP SIG
3.0B
5
6
7
0.75GrB
CN-BATT
8
130ZF5MS104
60B
5B
CN-GND
ECM
130ZF5MS103

Advertisement

Table of Contents
loading

Table of Contents