12)
CONTROL LEVER STROKE
Measure each lever stroke at the lever top
(1)
using a ruler.
When the lever has play, take a half of this
※
value and add it to the measured stroke.
(2)
Preparation
Keep the hydraulic oil temperature at
50±5˚C.
Measurement
(3)
Stop the engine.
①
Measure each lever stroke at the lever
②
top from neutral to the stroke end using a
ruler.
Repeat step ② three times and calculate
③
the average values.
Evaluation
(4)
The measured drift should be within the following specifications.
Model
HX130CR
HX130LCR
Kind of lever
Standard
Boom lever
Arm lever
Bucket lever
Swing lever
Travel lever
7-15
Maximum allowable
85±10
115
85±10
115
85±10
115
85±10
115
139±10
178
Unit : mm
Remarks