Hyundai HX130LCR Manual page 130

Hide thumbs Also See for HX130LCR:
Table of Contents

Advertisement

(2)
Case where pedal is tilted
13
7
When the push rod (13) is stroked, the spool (7) moves downwards.
Then port P is connected with port 1, and the oil supplied from the pilot pump flows through port
1 to generate the pressure.
When the pressure at port 1 increases to the value corresponding to the spring force set by tilting
the handle, the hydraulic pressure force balances with the spring force. If the pressure at port 1
increases higher than the set pressure, port P is disconnected from port 1 and port T is
connected with port 1. If it decreases lower than the set pressure, port P is connected with port
1 and port T is disconnected from port 1.
In this manner the secondary pressure is kept at the constant value.
Besides, in some type, when the handle is tilted more than a certain angle, the upper end of the
spool contacts with inside bottom of the push rod and the output pressure is left to be connected
with port P.
2-86
T
P
130ZF2RP04