Hyundai HX130LCR Manual page 250

Hide thumbs Also See for HX130LCR:
Table of Contents

Advertisement

DTC
HCESPN FMI
(Detection)
(When Travel EPPR Current is more than 10 mA)
10 seconds continuous, Travel EPPR drive current = 0 mA
5
(Cancellation)
(When Travel EPPR Current is more than 100 mA)
3 seconds continuous, Travel EPPR drive current ≥ 10 mA
(Detection)
10 seconds continuous, Travel EPPR drive current > 1.0 A
143
6
(Cancellation)
3 seconds continuous, Travel EPPR drive current ≤ 1.0 A
(Results / Symptoms)
1. Control Function – cruise control operation failure
(Checking list)
1. CN-246 (#2) – CN-54 (#39) Checking Open/Short
2. CN-246 (#1) – CN-51 (#40) Checking Open/Short
(Model Parameter) mounting Remote Cooling Fan EPPR
(Detection)
(When Remote Cooling Fan EPPR Current is more than 10 mA)
5
10 seconds continuous, Remote Cooling Fan EPPR drive current = 0 mA
(Cancellation)
(When Remote Cooling Fan EPPR Current is more than 10 mA)
3 seconds continuous, Remote Cooling Fan EPPR drive current ≥ 10 mA
(Detection)
145
10 seconds continuous, Remote Cooling Fan EPPR drive current > 1.0 A
6
(Cancellation)
3 seconds continuous, Remote Cooling Fan EPPR drive current ≤ 1.0 A
(Results / Symptoms)
1. Control Function – Remote fan control operation failure
(Checking list)
1. CD-52 (#1) – CN-51 (#9) Checking Open/Short
2. CD-52 (#2) – CN-51 (#14) Checking Open/Short
※ Some error codes are not applied to this machine.
G : General
Diagnostic Criteria
C : Crawler Type
W : Wheel Type
5-23
Application
G
C
W

Advertisement

Table of Contents
loading

Table of Contents