DISASSEMBLY
(1)
Select place suitable to disassembling.
Select clean place.
Spread rubber sheet, cloth or so on
overhaul workbench top to prevent parts
from being damaged.
(2)
Remove dust, rust, etc, from pump
surfaces with cleaning oil or so on.
(3)
Remove drain port plug (468) and drain oil
pump casing (271, 272).
(4)
Remove hexagon socket head bolts (412,
413) and remove regulator.
(5)
Place pump horizontally on workbench
with its regulator fitting surface down, and
remove flange socket (435) and remove
PTO unit (05).
Be careful about the attaching direction of
the PTO unit (05).
Before bringing regulator fitting surface
down, spread rubber sheet on workbench
without fail to prevent this surface from
being damaged.
(6)
In case the pump is provided without the
PTO unit (05), remove the cover (262) with
the hexagon socket head cap screws
(414).
8-13