ARM REGENERATION
The return flow from the arm cylinder rod side is pressurized by self weight of arm and so, returns to
port D4. The pressurized oil returning to port D4 enters the arm regeneration & breaker spool through
the arm holding valve and the arm 1 spool. It is supplied the arm cylinder head through internal
passage. This is called the arm regeneration function.
The amount of regeneration fluid is changed by movement of the arm regeneration spool. A few
fluids after P2 parallel passage is push piston "C" through the notch of arm regeneration spool and
selector spool. At this time, the selector spool is opened by pilot pressure from RCV.
Then, the arm regeneration spool shifts to right side and flow to tank pass increases and regeneration
flow decreases. Therefore, pressure of arm cylinder head increases, then, arm regeneration flow
decreases.
Furthermore, the arm regeneration cut pressure is supplied to the port Pb4 of spring opposite side
and arm regeneration spool is move into the right direction fully. The flow from the arm cylinder rod is
returned to the hydraulic oil tank and regeneration function is not activated. (The return fluid is
maximum condition)
Load check valve
P2 Parallel passage
Piston C
Selector spool
Pc40
Arm regeneration
cut pilot pressure
Pb4
Pc42
Arm in
pilot pressure
Arm regeneration
Arm regeneration
& breaker spool
& breaker spool
Arm summation passage
C4
D4
2-37
Arm 1 spool
Arm holding valve
Tank passage
P2 Bypass passage
125LCR2MC22