Hyundai HX130LCR Manual page 252

Hide thumbs Also See for HX130LCR:
Table of Contents

Advertisement

DTC
HCESPN FMI
(Detection)
(When Travel Speed Solenoid is Off)
10 seconds continuous, Travel Speed Solenoid drive unit Measurement
Voltage ≤ 3.0V
(Cancellation)
(When Travel Speed Solenoid is Off)
3 seconds continuous, Travel Speed Solenoid drive unit Measurement
Voltage > 3.0V
(When Parking mode is not)
4
(Detection)
(When Travel Speed Solenoid is Off)
10 seconds continuous, Travel Speed Solenoid drive unit Measurement
Voltage ≤ 3.0V
(Cancellation)
167
(When Travel Speed Solenoid is Off)
3 seconds continuous, Travel Speed Solenoid drive unit Measurement
Voltage > 3.0V
(Detection)
(When Travel Speed Solenoid is On)
10 seconds continuous, Travel Speed Solenoid drive current > 4.5 A
6
(Cancellation)
(When Travel Speed Solenoid is On)
3 seconds continuous, Travel Speed Solenoid drive current ≤ 4.5 A
(Results / Symptoms)
1. Control Function – driving in 1/2 transmission operation failure
(Checking list)
1. CN-70 (#1) – CN-52(#20) Checking Open/Short
2. CN-70 (#2) – CN-45(#B+ term) Checking Open/Short
※ Some error codes are not applied to this machine.
G : General
Diagnostic Criteria
C : Crawler Type
W : Wheel Type
5-25
Application
G
C
W