8)
SELF DIAGNOSIS FUNCTION
Procedure
(1)
Press the air recirculation button over 5 times within
Cancelled diagnosis function(normal function)
(2)
Error check
The corresponding error code flickers on the setup temperature display panel, the other symbol
·
will turn OFF.
Error code flickers every 0.5 second.
·
If error code is more than two, each code flickers 2 times in sequence.
·
Error code
·
Error code
11
12
14
15
(3)
Fail safe function
Error description
Cabin inside sensor (11)
Ambient sensor (12)
Duct (evaporator) sensor (14)
Temp actuator (15)
Mode actuator 1, 2 (16, 17)
Starting switch ON
2 seconds during pressing the AUTO switch
All symbol of LCD blink 5 times
Error check
Press AUTO switch
Description
Cabin inside sensor
Ambient sensor
Duct (evaporator) sensor
Temp actuator
25˚C alternate value control
20˚C alternate value control
1˚C alternate value control
If opening amount is 0 %, the alternate value is 0 %
If not, the alternate value is 100 %
The alternate value is vent
Switch OFF
System OFF
Error code
16
17
18
-
Fail safe function
5-93
3607A3CD69
Description
Mode actuator 1
Mode actuator 2
Intake actuator
-