ZyXEL Communications XS3800-28 User Manual page 351

28-port 10gbe l3 managed switch
Hide thumbs Also See for XS3800-28:
Table of Contents

Advertisement

Figure 261 SWITCHING > PPPoE Intermediate Agent > PPPoE IA Port VLAN (Stacking Mode)
The following table describes the labels in this screen.
Table 166 SWITCHING > PPPoE Intermediate Agent > PPPoE IA Port VLAN
LABEL
DESCRIPTION
Show Port
Port
Enter a port number to show the PPPoE Intermediate Agent settings for the specified VLANs on
the port.
In Stacking mode, the first field is the slot ID and the second field is the port number.
Show VLAN
Use this section to specify the VLANs you want to configure in the section below.
Start VID
Enter the lowest VLAN ID you want to configure in the section below.
End VID
Enter the highest VLAN ID you want to configure in the section below.
Apply
Click Apply to display the specified range of VLANs in the section below.
Port:
This field displays the port number specified above.
Slot / Port
In Stacking mode, it displays the slot ID and port number specified above.
VID
This field displays the VLAN ID of each VLAN in the range specified above. If you configure the *
VLAN, the settings are applied to all VLANs.
*
Use this row to make the setting the same for all VLANs. Use this row first and then make
adjustments on a VLAN-by-VLAN basis.
Changes in this row are copied to all the VLANs as soon as you make them.
Circuit-ID
Enter a string of up to 63 ASCII characters (except [ ? ], [ | ], [ ' ], [ " ], or [ , ]) that the Switch adds
into the Agent Circuit ID sub-option for this VLAN on the specified port. Spaces are allowed.
The Circuit ID you configure here has the highest priority.
Remote-ID
Enter a string of up to 63 ASCII characters (except [ ? ], [ | ], [ ' ], [ " ], or [ , ]) that the Switch adds
into the Agent Remote ID sub-option for this VLAN on the specified port. Spaces are allowed.
If you do not specify a string here or in the Remote-ID field for a specific port, the Switch
automatically uses the PPPoE client's MAC address.
The Remote ID you configure here has the highest priority.
Apply
Click Apply to save your changes to the Switch's run-time memory. The Switch loses these
changes if it is turned off or loses power, so use the Save link on the top navigation panel to save
your changes to the non-volatile memory when you are done configuring.
Cancel
Click Cancel to begin configuring this screen afresh.
Chapter 47 PPPoE
XS3800-28 User's Guide
351