2. Port configuration: digital input or output
The following table shows which tool can influence which section.
Tool
EtherCAT
WAGO I/O Field Web-
server
WAGO App I/O Field
WAGO IO-Link Configura-
tor
Note
Parameters via EtherCAT
Each time EtherCAT
and parameters to the module. Port configuration parameters that were set by the WAGO
I/O Field Webserver, the WAGO I/O Field app or the OPC UA client are overwritten.
If you have modified port configuration parameters via the WAGO I/O Field Webserver,
the WAGO App I/O Field, WAGO IO-Link Configurator or the OPC UA client, please note
that these changes are initially applied to the module, but the EtherCAT
writes the port configuration again the next time it starts up. If you want to change port
configuration parameters, set them in the configuration software of the EtherCAT
ter.

5.5.2 WAGO Webserver I/O Field

The WAGO I/O System Field module has an integrated Webserver. It can be accessed
with a standard Web browser in order to use the following functions:
• Display port information for ports X01, X02 etc.
• Display and modify module settings.
• User setup and management, as well as user login and logout
• Reset module to factory settings and restart firmware.
• Simulating inputs; forcing outputs
Examples of port information include:
• Display current measured values of the digital inputs and outputs: temperature, volt-
age, current and status on pins 1, 2 and 4
• Display the status information for the entire port
• Configure ports, e.g. set operating mode
• Show process data
The module settings include:
• Select method for obtaining IP address
• Select the origin of the configuration data used
• Display and enter maintenance information
• Reset module to factory settings.
Product manual | Version: 2.0.0
8DIO FLD EC DC 24V 2.0A
®
EtherCAT
Module
®
master
The EtherCAT
configures the 765 Series
module.
®
are always rewritten upon restart
®
communication starts up, the master transfers the configuration
Port Configuration
®
®
master
The EtherCAT
master sets the parameter selected by
the user on the basis of the parameters in the XML file
WAGO_series765.xml. These parameters configure
each individual port and determine whether the port is
used as a digital input or digital output (or is disabled).
Yes
Yes
Yes
Functions
Table 27: Parameterization Overview
®
master over-
®
mas-
29