Tektronix DG2040 User Manual page 158

Data generator
Hide thumbs Also See for DG2040:
Table of Contents

Advertisement

Step
Enhanced
DG2040 Data Generator
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
When no sequence is defined, all of the pattern data is output as a single
waveform as shown in Figure 3-62. If a sequence is defined, the sequence
ordering and repeat (Repeat Count) functions are applied as shown in Figure
3-63. The extended sequence functions (trigger input, event jump, etc.) are
ignored.
Pattern Data Output
Pattern Data
Trigger Input
Figure 3 62: Single Mode pattern data output (when no sequence is defined)
Line no.
Block
0
BK0
1
BK1
2
BK2
Line No.
0
BK0
BK1
Sequence Output
Trigger Input
Figure 3 63: Single Mode pattern data output (when a sequence is defined)
Pattern data is output not according to the internal clock, but rather according to
a clock signal generated manually with the STEP/EVENT button. Pattern data
is output using the method used by the Repeat item.
Pattern data is output as defined by the sequence. The extended sequence
functions (trigger input, event jump, etc.) are valid during this output. The
Repeat Count item setting is used for sequences for which the repeat count is
not set to Infinite. Figure 3-64 shows an example of an enhanced mode
sequence. Also refer to the description of the EDIT menu Make Sequence menu
on page 3-57.
BK0
Repeat Count
1
3
Pattern Data
2
1
2
BK1
BK1
BK2
BK2
Sequence
Reference
BK1
BK2
Trigger Input Wait
3 75

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dg203059021-1059021-15