Tektronix DG2040 User Manual page 146

Data generator
Hide thumbs Also See for DG2040:
Table of Contents

Advertisement

Undo
DG2040 Data Generator
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
The event jump operation occurs even if the block pattern has not been output
for the number of repeats set in the sequence program. When an event jump
operation occurs, a positive TTL-level pulse, from 194.5 to 214.5 clocks wide, is
output from the front–panel event output connector 180 to 200 clocks before the
block pattern switches. One half of one clock is the falling edge of the clock.
Event
Event Reception Period for Block B
Input
Event
Output
Data
Block A
Output
n: A value between 1 and the value determined by the iteration count
Note: If an event exists before the event out starts rising, the event jump will be made at
the next block. If the the event is coming after the event out starts rising, the event jump
will be performed at the block after the next block.
The number of clock varies depending on the pattern size of that block. This is because
the clock is generated from the ECL clock circuit by dynamically dividing into 9 or 10
cycles.
Figure 3 54: Event jump operation timing
After performing an edit function, you can press the Undo button to return to the
state immediately prior to your edit.
Refer to Note Below
194.5 to 214.5 Clock Cycles
194.5 to 214.5 Clock Cycles
180 to 200 Clock Cycles
The nth Output of Block B
Reference
Block C
3 63

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dg203059021-1059021-15

Table of Contents