DG2040 Data Generator
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Operation.
Do the following to set the scope.
Bottom button
Pop up menu
Execute Action
Select Set scope.
Set the number of scope elements using the
knob.
When Cut in the Action menu is selected, the cursor becomes an area cursor. The
data in the editing range is deleted, and data is filled in at the end of memory in
an amount equal to the amount of data deleted. The filled data (the tail) is set to
0. Note that the deleted data is inserted in the paste buffer and can be used as
paste data.
Before
Execution
After
Execution
Figure 3 24: Cut
When Copy in the Action menu is selected, the cursor becomes an area cursor.
The data in the editing range is copied to the paste buffer. The pattern data itself
is not affected.
When Paste-insert in the Action menu is selected, data in the paste buffer is
inserted at the current cursor position. The data after the cursor is moved to the
rear by the length of the pasted data. After the data is moved, data that exceeds
the set memory size is lost.
Cursor
Before
Execution
After
Execution
Figure 3 25: Paste insert
Area Cursor
Paste Buffer Data
Reference
Side button
OK
OK
Tail
3 35